A magnet is mounted on the fly wheel or the crank shaft so that it makes one revolution per cycle of the press. The Proximity Switch is located so that it picks up a signal when the Magnet passes by it and sends the signal to the Electronic Controller. The signal activates the Delay Timer which, after a set period of time, activates the Dwell Timer. The Dwell Timer opens the Solenoid Valve and holds it open until it completes its cycle. The Solenoid Valve now sends a signal to the UniValve portion of the nozzle via the Actuator Tubing. On the next pass of the Magnet the cycle will repeat itself.